Time-domain RFQ solver

TL;DR

For multiparticle runs, HELIX tracks an RFQ with time as the independent variable instead of cell by cell along z, by default whenever it can:

  • through the quasi-static 3-D field of its real vanes;
  • with space charge computed at a common time and periodic over the bunch spacing βλ;
  • with particles lost when they touch the electrodes.

This is how Toutatis and LINACSrfqSIM model an RFQ. On the PXIE RFQ it reproduces Toutatis's transmission, exit energy and loss locations at 0 and 5 mA, from the same input particles, with no tuning.

StepConfig.rfq_solver chooses the model:

value the RFQ is tracked by
"auto" (default) this solver whenever it can run the lattice and beam (see Requirements); otherwise the per-cell model (RfqCell), with a log notice that says why. A run that sets up the per-cell model explicitly — Simulation(rfq_geometry=...) other than "auto" ("off" is the card model), or a vane profile armed with apply_rfq_geometry — keeps the per-cell model
"time_domain" this solver; a case it cannot run stops the run with the reason
"cells" the per-cell model

Only the RFQ cells change solver: the solver finds the chain of RFQ_CELL elements itself, and everything before and after it (an LEBT, an MEBT) is tracked as before. The per-cell model remains the only model for envelope runs and backtracking. The results file records what tracked the RFQ (rfq_solver_used in provenance/) and, when "auto" kept the per-cell model, why (rfq_solver_note).

Where to choose it:

Place Setting
GUI Numerics tab → RFQ solver: Auto (time domain when possible), Per cell (two-term model) or Time domain (3-D vane field), and RFQ time steps per RF period
project file (.lgproj) convergence keys rfq_solver, rfq_td_steps_per_period, rfq_td_sc_every (absent: the defaults)
command line run / scan --rfq-solver auto\|cells\|time_domain [--rfq-td-steps N] (run)
Python dataclasses.replace(lat.step_config, rfq_solver="cells")
study spec "numerics": {"rfq_solver": "cells"}; rfq_td_steps can be a swept parameter
assistant run_mp with rfq_solver

The GUI choice applies to every multiparticle run started from it: the toolbar run, convergence and parameter scans, matching, and the error, failure and parameter studies.

Physics

Field. - The vanes are taken from the deck's RFQ_GEOM .vane file, read with its own pole numbering (pole 1 = +y, 2 = +x, 3 = −y, 4 = −x). - A deck without RFQ_GEOM gets its vanes from the RFQ_CELL cards, with the per-cell model's own geometry: - accelerating (±2) and transition (±4) cells: the two-term equipotential tip condition; - front-end (+3) and exit (−3) cells: the vanes flare as those cells' quadrupole ramp, R = r0/√C1 with C1 = sin³(πz/2L) or cos³(πz/2L), up to 3.5·r0; - tip radius: the card's Tc, else 0.75·r0; - vanes between the RFQ_GAP_RMS_FFS gaps, else where the flares reach 3.5·r0; - end-plate holes 1.076·r0.

On PXIE the card-built tips match the vane file to a median 0.03 % in the regular cells (95 % of points within 0.25 %), 3 % in the entrance flare and under 1 % in the exit flare, except one cell: the deck gives cell 201 as unmodulated, while the real vanes demodulate over its 53 mm. - Each vane is a tip arc of transverse radius ρ(z) at tip distance R(z) from the axis, continued by flat flanks. - The grounded end plates sit at the chain's two ends, at the gaps given by RFQ_GAP_RMS_FFS: 2.5 mm thick, with a hole of 6.0 mm × r0 / 5.576 mm (PXIE's proportion; r0 from the first and last cards). - Laplace's equation is solved on a quadrant grid (the pole pairs are mirror images): - second-order finite differences; - Shortley–Weller cut cells at the curved surfaces in all three directions; - overlapping z windows, each padded by 20 mm; - algebraic multigrid (pyamg). - Grid: 0.1 mm transversely; longitudinally the shortest cell length / 32. - The near-axis potential is stored and interpolated tricubically, with E = −∇φ taken from the interpolant. - The RF time dependence multiplies the static field: E(r, t) = E(r)·sin(ωt). - Accuracy: on an electrode set whose exact solution is known (two-term equipotentials), the solver's error is 5×10⁻⁵ of V/2 at 0.1 mm, and second order in the step.

Push. - Kick–drift–kick leapfrog (velocity Verlet) in (r, γβ), with the signed species charge. - 48 steps per RF period by default (rfq_td_steps_per_period). - On PXIE, 48 and 96 steps give the same transmission, energy and emittances. Toutatis's own PXIE runs used 12 steps per period, which shifts the 5 mA transmission by about 2 points.

Space charge. - Particles are deposited (cloud in cell) at a common time on a grid one bunch spacing βλ long, periodic in z, open in x and y. - The solver works mode by mode: an FFT along z, then for each mode k the 2-D Green's function K₀(|k|r)/2π (−ln r/2π for k = 0), convolved on a doubled transverse grid. - This is the field of an infinite train of identical bunches. For the DC beam at the entrance that is exact; through the buncher it supplies the neighbouring bunches. - The grid adapts to the beam: - the transverse grid spans ±4.5 rms; - the cells per period follow the bunch core length. - The kick is applied every rfq_td_sc_every = 4 steps. - The charge per macro-particle is the usual I/f/N_launched. - The space-charge compensation factor applies inside the RFQ as it does elsewhere. - Vane image charges are not included yet. On PXIE at 5 mA they change the core field by under 1.5 %, and the halo field near the vanes by about ±14 %.

Injection and exit. - The beam enters as given at the chain entrance. Each particle's phase becomes an arrival time, and the particle is drifted back to a common start time upstream of the entrance plate. - At every cell exit, each particle's crossing is recorded, interpolated inside the time step. - A DC beam is one period of a steady train, with no phase origin of its own. The bunch core is centred at the RFQ exit, on the reference particle's phase. - The RFQ's buckets need not line up with the injection window: particles injected near its edges are captured one period earlier or later. Each captured particle is counted in the bucket it ends in — in a steady train it is the neighbouring window's particle of the main bunch — so the accelerated beam leaves as one bunch, with or without periodic_phase (PXIE at 0 mA: σφ 6.4°). - A slow particle that is not captured keeps its lag. With periodic_phase (the PXIE projects set it) such particles are folded onto the bunch after every cell, as after any element; σφ of all particles at the PXIE exit is 6.9° with the fold and about 2000° without it. - Every particle's shift is a whole number of periods, the same at every cell, so its phase is continuous through the RFQ. Between the input and the first cell the whole beam moves by the constant that centres the exit bunch — for a DC beam, a relabelling of time. - A DC beam that has passed a static electric element (einzel lens, extraction column) is accepted. As in a per-cell run, HELIX then never marks it a bunch train, so periodic_phase does not fold it. - The reference particle is the one the RFQ cells produce in a per-cell run, so the reference itself, and the phasing of the RF elements downstream, are the same in both solvers. The beam's centroid can sit off it in energy: on PXIE the bunch leaves 23 keV above the reference (Toutatis reports about +28 keV), mostly from cell 201 (see Why the exit energies differ). The run records this offset (exit_w_offset_kev) and warns when it exceeds 0.5 % of the energy; downstream RF elements see the beam off their design energy by that much, as in TraceWin with a Toutatis RFQ. - Results keep one row per cell, named after the cell. With record_substeps each cell gets 4 rows, the last at its exit; they sit at positions where a per-cell run records a row too, with the same reference particle. (The per-cell model records every 0.1 mm, tens of thousands of planes over an RFQ, too many to keep for every particle.) - Downstream, the space-charge solver's bunch-train setting (neighbour bunches on while the bunch is long, see neighbour images) is left as a per-cell run leaves it: it is evaluated from the bunch length at every cell exit.

Losses. - A particle is lost when it is inside metal (a vane tip, a vane body or an end plate), turns back, or is still inside the RFQ after three times the entrance transit time. - It is also lost when it leaves the stored field region, the near-axis box beyond the vane tips (7.9 mm from the axis for PXIE), between the vanes. No field is stored there. Without this rule such a particle flew on in zero field: one did, to 1 m off axis at the exit, and its offset dominated the rms rows along the RFQ. - Each loss is recorded at the particle's own z, with the name of the cell it died in.

Statistics of the accelerated beam. Some particles fall behind the bunch: they lag the reference particle by more than half of its energy gain. On PXIE at 5 mA, about 10 in 15 500 leave the RFQ near 28 keV, 2 MeV below the bunch, and a few more are lost on the vanes later. They stay in the beam until then: the transmission, the losses and the exported distribution count them. But with rfq_stats_accelerated (on by default), the recorded statistics leave them out. These are the rms sizes, emittances, energy spread, Twiss parameters and density. Each particle is left out from the cell after the last one where it lagged the reference energy by less than a tenth of the reference gain, that is, from where it fell behind the bunch, so every plot and tile describes the accelerated beam. Otherwise those few particles set the exit energy spread: 57 keV against 8.1 keV. Turn the setting off, with Numerics → RFQ statistics: accelerated particles only or --rfq-stats all, to count every surviving particle. The run's log line gives the count.

Results on the PXIE RFQ

Toutatis's own 7786 input particles at the RFQ entrance (H⁻, 30 keV → 2.1 MeV, 162.5 MHz, 60 kV, 203 cells):

Toutatis time-domain, vane file time-domain, vanes from the cards per-cell (antisym)
transmission, 0 mA 98.37 % 98.50 % 98.19 % 98.82 %
transmission, 5 mA (3.893 mA alive) 80.40 % 80.91 % 79.28 % 83.48 %
exit ⟨W⟩, 5 mA 2.1211 MeV 2.1221 MeV 2.0998 MeV 2.0988 MeV

The losses along z follow Toutatis: the counts of particles alive at the cell exits outside the buncher's loss burst agree within 0.6 % of the input (0.2 % at 0 mA), and the burst (about 1260 particles at 5 mA between 0.65 and 1.08 m) sits at the same place, the time-domain losses trailing by about 5 cm. At 5 mA, σx and σy at the cell exits lie within a median of 8 % of Toutatis's table (the median over the cells beyond 0.25 m of |σ_HELIX/σ_Toutatis − 1|). That table holds fixed-time snapshots, while HELIX records fixed-z crossings.

Exit emittances (normalised rms, of the accelerated particles, W > 2.0 MeV — Toutatis's exit file also holds about ten unaccelerated particles, which raise its 5 mA x-emittance from 0.387 to 0.465):

mm·mrad, x / y Toutatis time-domain
0 mA 0.300 / 0.298 0.314 / 0.304
5 mA 0.387 / 0.352 0.396 / 0.407

At 5 mA the vertical emittance is 16 % above Toutatis's, the one clear difference left. It is not the time step: at Toutatis's 12 steps per period it rises to 0.427. Vane image charges, which Toutatis includes and this solver does not yet, are the leading candidate.

Why the exit energies differ. Up to cell 199 the vane file and the vanes built from the cards give the same bunch energy, within 1 keV. The deck gives cell 201 as unmodulated (A10 = 0), while the real vanes demodulate gradually over its 53 mm and still accelerate the bunch there: the vane file ends 21 keV higher. The per-cell model, which follows the cards, ends 23 keV low against Toutatis for the same reason.

Regression mode. cards_geometry.two_term_field_map gives the time-domain solver the per-cell model's own analytic two-term field. From the same particles at 0 mA it gains the same energy as the per-cell model (2.0997 and 2.0981 MeV for the accelerated particles), so the cards' synchronous phases agree with a single RF clock. The median deviations of σx and σy at the cell exits from the run on the real vanes are:

σx σy
time domain, vanes built from the cards 1.8 % 2.0 %
time domain, the cards' two-term field 14 % 15 %
per-cell model 38 % 11 %

The field of the real vanes, which the two-term form approximates, accounts for about 15 % in beam size; the per-cell model's transverse treatment adds most of the rest in x.

Using it

Requirements: - the vanes: an RFQ_GEOM card naming the .vane file, or no RFQ_GEOM card (the cards give the electrodes, see Physics); - a DC (continuous) beam at the RFQ entrance; - one contiguous chain of RFQ_CELL elements, with only markers between cells; - one vane voltage; - no misalignment, or the same misalignment on every cell; - at least 3 cells, and mirror-symmetric pole pairs (tip distances and radii equal to 1 µm, equal voltages, one voltage along z); - pyamg (installed with HELIX), to build a field map (a cached map loads without it).

These are checked when the run starts, before anything is tracked. With "auto" a violation means the RFQ is tracked cell by cell, with a log notice; with "time_domain" it raises an RfqTdError. A deck that names a vane file that cannot be read is never run from the cards' electrodes instead: "time_domain" fails, "auto" uses the per-cell model.

First run. The field map is built once: about three minutes on 8 cores for PXIE (about 200 MB). It is cached under the user cache directory (~/Library/Caches/HELIX/rfq_td on macOS, or HELIX_CACHE_DIR), keyed by the vane geometry, the cell edges and the solver settings — not the voltage: a voltage scan reuses one map. The cache keeps the most recently used maps within 4 GB (HELIX_RFQTD_CACHE_GB). The GUI status bar shows the build window by window; Stop ends the run as stopped, and nothing is cached. - Two processes that need the same map build it once: the second waits, and Stop ends the wait. A lock left by a process that died is taken over; an unreadable map is rebuilt. - Inside a multiprocessing pool worker (e.g. parallel CMA-ES matching) the map is built in that one process. - A window whose Laplace solve does not converge stops the build with an error; nothing is cached.

Run time (PXIE, 8 cores): 7786 particles in about 4 s at 0 mA and 50 s at 5 mA with space charge; 100 000 particles at 5 mA in 1.5 minutes. Identical runs give bitwise identical results, for any number of threads, and a field map built afresh on the same machine (a cleared cache) is bit for bit the one it replaces: the multigrid solver's set-up, which draws a random start vector, runs with numpy's global generator in a fixed state (linac_gen.core.amg.seeded), as does the per-cell model's vane-geometry profile solve.

Settings (StepConfig):

field default meaning
rfq_solver "auto" "auto": this solver when it can run, else the per-cell model; "time_domain": always this solver; "cells": the per-cell model
rfq_td_steps_per_period 48 leapfrog steps per RF period
rfq_td_sc_every 4 steps between space-charge kicks
rfq_stats_accelerated True statistics leave out the particles that leave the RFQ unaccelerated (see Physics)

Not supported yet (with "auto", these run on the per-cell model): - image charges; - displaced or deformed vanes (a full-domain field solve); - vane voltage varying along z; - a bunched input beam; - bunch-train (multibunch) runs; - envelope mode and backtracking, which keep the per-cell model (backtracking through the RFQ warns that it does).

Plots. The Results tab's RFQ panels draw these vanes, their field map once it is cached (on-axis field, peak surface field against the Kilpatrick limit) and the run cell by cell.

Source

  • linac_gen/rfq_td/geometry.py: electrodes and the loss test.
  • linac_gen/rfq_td/cards_geometry.py: electrodes from the RFQ_CELL cards.
  • linac_gen/rfq_td/laplace.py, build.py, fieldmap.py: field solve, cache and interpolation.
  • linac_gen/rfq_td/space_charge.py: periodic-train Poisson solver.
  • linac_gen/rfq_td/tracker.py: time loop.
  • linac_gen/rfq_td/chain.py: how the tracker runs and replays the RFQ.
  • linac_gen/csrc/rfq_td_kernels.cpp: the compiled field gather and leapfrog step.